Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

Health Physics

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Convertors
  • Check Sources
  • Instrument Cases

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m334ab_front_angle21
m334ab_front_angle21m334ab_front9m334ab_side5

Model 334AB-G

Alpha-Beta Particulate Monitor

Part Number: 48-3864-G

Features

  • Integrated LCD and Touch Screen Display
  • Acute and Chronic Dose, Concentration, and Flow Logging Measurements
  • Radon Compensation
  • Built-In Gamma Guard Detector
  • American or SI Units of Measurement
  • 8-Hour Battery Life

The Model 334AB-G (a replacement for the Model 334AB) is a lightweight, battery-powered, alpha-beta air monitor that can be used as a portable workplace monitor or a portable CAM (continuous air monitor) for emergency-response assessments. Its design provides workers with an early warning of an airborne release of alpha- or beta-emitting particulates. The instrument can monitor up to two alpha isotopes of interest simultaneously with beta monitoring.

The Model 334AB-G has an internal 7-LPM pump. (An external pump with a higher flow rate is available as an option.) The integrated LCD and touchscreen displays information on instrument status and readings during operation. The estimated dose of the isotope(s) of interest and the instrument status are displayed at all times. A visual/audio alarm stack also indicates instrument status. An ion-implanted silicon detector and 1024-channel multi-channel analyzer feed data to the embedded processor board to perform beta detection and alpha spectral analysis for radon background compensation.

Background Subtraction Using Peak Shape Fitting

State-of-the-art alpha peak fitting quantifies the alpha and beta counts from radon and thoron progeny. This technique uses the profiles of multiple alpha isotope peaks to create a composite curve which best fits the actual alpha spectrum. Because the individual radon peaks are independently determined, the beta background compensation is impervious to radon equilibrium changes and contributes to low probability of false alarms.

Guard Detector

An internal guard detector provides real-time beta compensation for changing gamma background levels. An adjustable gamma subtraction factor allows for correction of slight differences in beta and guard count rate in a fixed gamma field to produce proper energy response.

Sensitivity and Response Time

The Model 334AB-G’s sensitivity varies primarily as a function of the window time. The longer Chronic Window has improved sensitivities over the shorter Acute Window time. Sensitivity is reported in Minimum Detectable Concentration (MDC) in Bq/m3 (DAC) and Minimum Detectable Dose (MDD) in Bq-h/m3 (DAC-h).

 

  • Specifications
  • Options
  • Documents
  • Specifications
  • Options
  • Documents

Specifications

Sampling Head and Flow

  • Detector: solid-state ion-implanted silicon (450 mm2 active area, 300 µm depletion)
  • Air Flow Measurement: electronic mass flow control
  • Pump: internal diaphragm-type, 7.0 LPM max flow rate
  • Filter: 37 mm (1.5 in.) PTFE membrane or glass fiber filter (25 mm [1 in.] collection area)

Beta Data Analysis

  • Single beta channel with upper/lower discriminator setting
  • Gamma guard detector provides real-time compensation for changing gamma background levels
  • Acute (fast response, 120 sec. window) and chronic (high sensitivity, 240 min. window) measurements, plus net count rate alarm
  • Beta Efficiency: 7 - 18%, energy dependent

Alpha Data Analysis

  • MCA: 1024-channel ADC binned to 256 channel alpha spectrum
  • Radon compensation with alpha peak-shape-fitting, plus fixed background subtraction
  • Acute (fast response, 120 sec. window) and chronic (high sensitivity, 240 min. window) measurements, plus net count rate alarm
  • Monitoring of up to two alpha isotopes of interest
  • Alpha Energy Range: 1.0 - 9.0 MeV

Operation

  • Processor: Windows CE-based
  • Max. Count Rate: 600,000 (alpha + beta)
  • Source Response Check diagnostic
  • Calibration: electro-plated stainless steel sources required for efficiency calibration, 32 mm dia. with 25 mm active area
  • Display: 140 mm (5.5 in.) LCD resistive touch screen with backlight; Upper window shows dose and instrument status; Lower window shows either historical readings and battery status or current alpha spectrum; Top menu bar provides access to configuration and calibration functions
  • Display Update Rate: 1 to 5 sec. (adjustable)
  • Control Buttons:
    • Units: cycles the upper window display units between Bq-h/m3, Bq, CPM, and Bq/m3 (or DAC-h, pCi, CPS, and DAC)
    • Alarm Ack: silences alarm audio and clears latched alarms
    • Channel: cycles the upper window display between beta, alpha isotope channels, and flow rate
  • Alarms: separate chronic dose, chronic concentration, and acute dose alarms can be set for beta measurements and for each alpha isotope. Visual/audio alarm stack includes red alarm light and audible alarm (other indicator options are available). Alarm audio intensity is 94 dB at 1 m (3 ft). Recognizes and alarms on any equipment failure.
  • Data Logging: acquired data is saved in CSV format to internal memory or to an SD memory card. Logged data includes acute and chronic dose readings, as well as spectrum log files. A detailed log trend of at least three days of data can be shown in the display.

Physical

  • Temperature Range: -20 to 50 °C (0 to 122 °F)
  • Humidity: 0% to 100% (non-condensing)
  • Environmental Rating: IP rating of 53
  • Power: 8.4 V Li-Ion battery (6.6 Ah, 8-hour run-time, 4-hour charge time) or wall mount transformer (100 - 250 Vac, 50 - 60 Hz, single phase)
  • Size (W x H x D): 25 x 30 x 13 cm (10 x 12 x 5 in.)
  • Weight: 3.8 kg (8.3 lb)

Options

OptionDescriptionPart Number
RadNet Client Software Data/Status monitoring of up to 50 instruments simultaneously, requires RadNet Output option (PN 88-4348 or 88-4368). 88-4350
RadNet Output via WiFi Data/Status output over WiFi (RadNet protocol, internal antenna). 88-4348
RadNet Output via Ethernet Data/Status output over Ethernet (RadNet protocol). 88-4368
ASCII Output via RS-232 Data/Status output over RS-232 (ASCII protocol, RJ9 connector). 88-4366
ASCII Output via WiFi Data/Status output over WiFi (ASCII protocol, internal antenna). 88-4367
ASCII Output via Ethernet Data/Status output over Ethernet (ASCII protocol). 88-4369
External Pump Configuration Adds 10 mm (3/8 in.) hose barb for connection to external pump (not included). Includes mass flow sensing. 88-4362
In-Line Head (Remote Sampler) In-line head configuration to remote sample inlet up to 1.5 m (15 ft.). Requires External Pump Configuration (PN 88-4362) and external pump (not included). 88-4365
Wireless Access Point 802.11b/g wireless access point, preconfigured for compatibility. 88-4349
1.5 µm Pore Speclon Filters Speclon PTFE membrane filters, size: 1.5 µm x 37 mm, box of 100. 88-4351

Documents

  • Data Sheet
  • Product Manual

Related Products

m334a
Model 334A
Results 1 - 1 of 1

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.