Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

Health Physics

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Convertors
  • Check Sources
  • Instrument Cases

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m30-7
m30-7Model 30-7 Series

Model 30-7 Series

Lightweight Digital Neutron Survey Meter

Model 30-7 Part Number: 48-4192
Model 30-7B Part Number: 48-4309

Features

  • Small & Light 19.5 cm (7.7 in.) REM Ball
  • Moderated Neutron Detector
  • Digital Display with Adjustable Viewing Angle
  • Range: 0 to 99.9 mSv/h (0 to 9.99 rem/hr)
  • Low-Weight Unit Provides Same Readings as Standard REM-ball from Bare AmBe and Lower Energies
  • Includes Adjustable Shoulder Strap

The Model 30-7 Series are handheld, lightweight neutron dose detectors that join the Model 30 digital meter with a 19.5 cm (7.7 in) diameter REM ball containing a 3He detector. The instruments use similar detectors that only differ by the boron concentration in the internal borated layer. The Model 30-7 detector has a lower boron concentration and offers a greater sensitivity, typically 10 cpm per µSv/h (100 cpm per mrem/hr), but tends to overrespond in the 5 keV range. The Model 30-7B detector has a higher boron concentration and a lower sensitivity, typically 4.5 cpm per μSv/h (45 cpm per mrem/hr), but does not have the same overresponse issue as the Model 30-7.

Three modes of operation – RATE, MAX, and COUNT – are available for the user. Measurements can be collected in two sets of units (primary and secondary) for RATE and MAX modes in cps, cpm, rem/hr, or Sv/h units. An internal switch is used to enable or disable the front-panel setup feature to protect desired settings from inadvertent modification. Setup is also available via the Lumic calibration software (see Options tab).

Each instrument features a large, easily-readable LCD (liquid crystal display) that may be rotated for maximum ease of use by the operator. The connecting cable is threaded through the rugged carrying handle to simplify use. In addition, the display unit may be detached from REM ball, permitting the operator to position the detector and the display unit to best advantage within the limits of the cable length. Other features are an audio warning tone and easy, intuitive, user-friendly design. Splash-resistant construction allows the Model 30-7 Series to be used in outdoor environments. The display body is constructed of lightweight, durable, high-impact plastic.

 

  • Specifications
  • Graphs
  • Options
  • Documents
  • Firmware Updates
  • Specifications
  • Graphs
  • Options
  • Documents
  • Firmware Updates

Specifications

Indicated Use
Neutron dose rate
Detector 3He proportional detector, 1.6 x 2.5 cm (0.6 x 1.0 in.) (D x L), surrounded by a 19.5 cm (7.7 in.) diameter polyethylene sphere with internal borated layer
Measurement Range 0 to 99.9 mSv/h (0 to 9.99 rem/hr)
Sensitivity (bare AmBe neutrons) Model 30-7: Typically 10 cpm per μSv/h (100 cpm per mrem/hr) 
Model 30-7B: Typically 4.5 cpm per μSv/h (45 cpm per mrem/hr) 
Energy Response Provides approximate inverse RPG curve for neutrons from thermal through 7 MeV, provides response up to 12 MeV (see Energy Response Curve on Graphs tab). Model 30-7 tends to overrespond in the 5 keV range.
Linearity Reading within 10% of actual value
Gamma Rejection (137Cs gamma) < 10 cpm through 0.1 Sv/hr (10 R/hr)
LCD Display 3 digit LCD with large 13.4 mm (0.53 in.) digits, low-battery indicator, MAX, ALARM, MUTE
Units: (k)cps, (k)cpm, (µ)(m)Sv(/h), (µ)(m)rem(/h)
Display Range
  • 0.0 cps to 99.9 kcps
  • 0.00 cpm to 999 kcpm
  • 0.00 µSv/h to 999 Sv/h
  • 0.00 µrem/hr to 999 rem/hr
Display range can be set to limit display to calibrated range
Backlight Built-in ambient light sensor automatically activates low-power LED backlight, unless internal dipswitch is set to continuous-On (will reduce battery life). Alarm light intensity varies based on ambient light levels.
Controls
  • ON/OFF/ACK: Long press to turn ON; Tap to acknowledge alarms and silence alarm tone; Press to reset Sigma Audio alarm, turn “click” audio On/Off, turn Sigma Audio beep On/Off; Press and hold for OFF
  • UNITS: Long press changes the units between count rate (cpm, cps) or dose/exposure (µSv/h, rem/hr)
  • MODE: Long press alternates between NORMAL (count rate), MAX (captures peak rate), and COUNT (user-selectable preset count time from 0 to 10 minutes). Number of modes can be reduced in setup.
Response Time User-selectable from 1 to 60 seconds, Auto-Response Rate FAST or SLOW, or Fixed FAST and SLOW
Alarms Count rate, exposure/dose, and scaler alarm setpoints adjustable over the display range
Overload High count rate saturation protection prevents false display of lower count rates
Zero Protection After a user-settable time interval (default 60 seconds) of no pulses from the detector, the instrument will flash zero reading and the alarm audio will be triggered
Dead Time Correction Employs first and second order corrections for extended performance
Operating Voltage Approximately 1200 Vdc
Threshold -2 mV
Audio Greater than 75 dB at 0.6 (2 ft), approximately 4 kHz
Click Audio Divide x1, x10, x100, x1k
Power Two alkaline or two rechargeable “AAA” batteries
Battery Life Approximately 100 hours of operation, 24-hour low battery warning
Construction High-impact plastic with water-resistant rubber seals and separate battery compartment
Working Environment Splashproof shields for outdoor use
Temperature Range -20 to 50 °C (-5 to 122 °F)
May be certified for operation from -40 to 65 °C (-40 to 150 °F)
Environmental Rating NEMA rating of 3x or IP rating of 52 with audio hole seal option (hole seal option will reduce maximum volume by approximately 10 dB)
Size Display Unit: 8.5 x 8.0 x 4.8 cm (3.4 x 3.1 x 1.9 in.) (H x W x L)
Detector: 19.5 cm (7.7 in.) diameter REM ball with 3He detector (1.6 x 2.5 cm) (D x L)
Weight Display Unit: 174 g (0.38 lb)
Detector: 4.6 kg (10.2 lb)

Graphs

M30 7B vs NRD energy response curve


Options

OptionDescriptionPart Number
Lumic Calibration Kit
Lumic Calibration Software allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. This software also includes a calibration wizard (guides the user through calibration steps) and a plateau wizard (determines the optimal detector operating voltage).

The kit includes Lumic Calibration Software versions 1.0 and 2.0, a Model 3000 Series USB cable, and a Model 30 family USB cable.
4519-865
Lumic Configuration Kit
Lumic Configuration Software allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. Does not include calibration or plateau wizards.

The kit includes the Lumic Configuration Software, a Model 3000 Series USB cable, and a Model 30 family USB cable.
4519-747
Headphone Jack
Adds headphone jack to instrument. 4498-697
Audio Hole Seal Option Reduces audio volume output. 4498-913
case_web
Case for Neutron Meters
Rugged transport and storage case. 2310377
2311487-neutron-case_600px
Case for Neutron Meters
Rugged transport and storage case. Has wheels and extendable handle. 2311487

Documents

  • Data Sheet
  • Product Manual (Model 30)
  • Model 42-49 & 42-49B Neutron Detector Manual
  • CE Certificate
  • Ludlum Neutron Meters Comparison Table

Firmware Updates

In order to use the latest Lumic Calibration Software*, you may need to update the firmware on your instrument. (All new instruments will be compatible with the latest software version.) Use the table below to determine the firmware requirement for your instrument.

Software Version Compatible Models Required Firmware
Lumic 1.0 30, 30-4, 30-6, 30-7, 35, 79 2.x or lower
3000, 3001, 3005, 3006, 3019, 3276 N34 or lower
3002, 3277 N12 or lower
Lumic 2.0 30, 30-4, 30-6, 30-7, 35, 79 3.x or higher
3000, 3001, 3005, 3006, 3019, 3276 N40 or higher
3002 N20 or higher
3003, 3014, 3078 N/A

*Note: If you purchased the original Lumic 1.0 software, you are eligible for a free copy of Lumic 2.0. Please contact your local sales representative or Ludlum Measurements to receive your copy.


To update the firmware on your instrument:
  1. Download the appropriate instructions file (PDF) for your instrument.
    IMPORTANT: The firmware update instructions are model number specific. You must use the instructions for your specific instrument model. See table below.

    Model Instructions File
    30, 30-4, 30-6, 30-7, 35, 79 Lumic Firmware Update Instructions (Model 30/35/79 Series)
    3000, 3001, 3002, 3005, 3006, 3019, 3276 Lumic Firmware Update Instructions (Model 3000 Series, Gen 1)
    3003, 3014, 3078 Lumic Firmware Update Instructions (Model 3000 Series, Gen 2)
  2. Download the latest Lumic Firmware Updater Software.
  3. Determine the printed circuit board number your instrument has. To do this, you must open the instrument can and find the number on the circuit board.
  4. Using the drop-down selectors below, select your instrument model and printed circuit board number. This will populate a list of available firmware downloads for your instrument.

Related Products

m3007-angle
Model 3007 Series
m12-4-7_no_bkg_500
Model 12-4-7
m30-4_angle
Model 30-4
m30_face_133764959
Model 30
m12-4a
Model 12-4
2241-4_neutron_mete_cmyk_500px
Model 2241-4
m2363-w-prescila8
Model 2363 with 42-41L
m15-lft-angle-trans-lower-detector-5-merged_500px
Model 15
Results 1 - 8 of 8

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.